Optimization of a sequential alignment verification and positioning system (SAVPS) for proton radiosurgery
2005
- 82Usage
Metric Options: CountsSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Metrics Details
- Usage82
- Downloads64
- Abstract Views18
Thesis / Dissertation Description
Functional proton-beam stereotactic radiosurgery requires sub-millimeter alignment accuracy. A patient tracking system called Sequential Alignment and Position Verification System (SAVPS) is under development at Loma Linda University Medical Center. An optical positioning system (OPS), manufactured by Vicon Peak, has been chosen to verify the correct alignment of the target with the proton beam axis. The main objective of this thesis is to optimize an existing version of SAVPS by conducting error analysis. An image processing algorithm was developed and applied to estimate the error introduced by the Patient Positioning System (PPS) in order to derive the true error of the SAVPS.
Bibliographic Details
Provide Feedback
Have ideas for a new metric? Would you like to see something else here?Let us know