Absolute frequency measurement of the level of neutral using two-photon spectroscopy
Physical Review A, ISSN: 2469-9934, Vol: 104, Issue: 4, Page: 42812
2021
- 6Citations
- 159Usage
- 4Captures
Metric Options: Counts1 Year3 YearSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Metrics Details
- Citations6
- Citation Indexes6
- Usage159
- Downloads149
- Abstract Views10
- Captures4
- Readers4
Article Description
We report absolute frequency measurements on the level of neutral using sub-Doppler two-photon spectroscopy. The absolute center-of-gravity energy for the level is determined to be , a factor of 170 times improvement over the previous measurement from 1964 of . This measurement also corrects a discrepancy with the previously measured value. The hyperfine coefficients were found to be and , which are consistent with previous results.
Bibliographic Details
https://scholarworks.smith.edu/bio_facpubs/289; https://scholarworks.smith.edu/phy_facpubs/87; https://scholarworks.smith.edu/phy_facpubs/96
http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=85117956027&origin=inward; http://dx.doi.org/10.1103/physreva.104.042812; https://link.aps.org/doi/10.1103/PhysRevA.104.042812; http://harvest.aps.org/v2/journals/articles/10.1103/PhysRevA.104.042812/fulltext; https://link.aps.org/article/10.1103/PhysRevA.104.042812; https://scholarworks.smith.edu/bio_facpubs/289; https://scholarworks.smith.edu/cgi/viewcontent.cgi?article=1293&context=bio_facpubs; https://scholarworks.smith.edu/phy_facpubs/87; https://scholarworks.smith.edu/cgi/viewcontent.cgi?article=1086&context=phy_facpubs; https://scholarworks.smith.edu/phy_facpubs/96; https://scholarworks.smith.edu/cgi/viewcontent.cgi?article=1095&context=phy_facpubs
American Physical Society (APS)
Provide Feedback
Have ideas for a new metric? Would you like to see something else here?Let us know