Drive Plate Mass Polar Moment of Inertia in Stokeo Type Resonant Column Devices
2015
- 402Usage
Metric Options: CountsSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Metrics Details
- Usage402
- Downloads332
- Abstract Views70
Thesis / Dissertation Description
The calibration procedure employed by researchers at the University of Arkansas (UA) to calibrate two Stokoe-type resonant column torsional shear (RCTS) devices is presented herein. Specifically, the development of a device-specific calibration process to determine the mass polar moment of inertia of the RCTS drive plate assemblies (J0), as a function of frequency, is described. Three aluminum calibration specimens and three stainless steel masses with known geometric and material properties were utilized to experimentally determine the J0 values. Experimental data collected by researchers at the University of Arkansas and obtained from other sources (Utah State University, the University of Texas at Austin, the University of Colorado at Boulder, the University of Southampton, Rensselaer Polytechnic Institute, and Kleinfelder) were analyzed utilizing two different data reduction methods. Key findings include the J0 values for two UA drive plates (2.743∙10-3 kg∙m2 and 2.750∙10-3 kg∙m2 for Devices 1 and 2, respectively) and fitted calibration functions for J0, as a function of frequency, for multiple RCTS devices. For samples with low natural frequencies (less than 100 Hz), the frequency dependence of the mass polar moment of inertia was determined to have negligible effects (less than 1.1 percent) on the calculated shear wave velocity for dry Ottawa sand.