Closed System Electrical Conductance Apparatus for Non-Aqueous Systems
Proceedings of the Iowa Academy of Science, Vol: 64, Issue: 1, Page: 242-246
1957
- 39Usage
Metric Options: CountsSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Metrics Details
- Usage39
- Downloads32
- Abstract Views7
Artifact Description
Studies of electrical conductance in non-aqueous solvents is often hampered by the ability of the solvents to absorb moisture and/or carbon dioxide from the atmosphere. Even small traces of these impurities may alter considerably the conducting properties of the solution and render the measurements invalid. The errors become especially important when the solutes are highly hygroscopic themselves. The usual technique for cases where contact of solutions with the atmosphere is to be avoided is to prepare them in a conventional dry-box. This renders the operation tedious and time-consuming especially when a number of exact dilutions have to be made. These disadvantages could be eliminated by the use of a closed system in which the solvent is purified, the solution prepared, accurate dilutions made, and the electrical conductance measured in a completely inert atmosphere. A closed system has been recently described (1) in which it is possible to prepare the solutions and to measure their conductances out of contact with atmospheric moisture. This apparatus is only applicable when the solute is in a liquid state and it is not convenient for carrying out precise successive dilutions. A modification which seems to eliminate the difficulties of this apparatus has been constructed, and its performance has been found to be quite satisfactory in a study of the electrical conductance of interhalogen compounds in non-aqueous solvents (2).
Bibliographic Details
Provide Feedback
Have ideas for a new metric? Would you like to see something else here?Let us know