Design of an accelerator-based shielding experiment at the NASA Space Radiation Laboratory relevant to enclosed, shielded environments in space
2022
- 194Usage
Metric Options: CountsSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Metrics Details
- Usage194
- Downloads115
- Abstract Views79
Report Description
Recent calculations indicate that the dose equivalent in an enclosed, shielded environment in a galactic cosmic ray field will increase or remain unchanged when shielding thickness increases beyond 20 to 30 g/cm2. This trend is seen out to 100 g/cm2, beyond which calculations were not run since depths greater than this are not envisioned for human missions in deep space. If these calculations are accurate, then an optimal shielding thickness (or narrow range of thicknesses) exists, with important implications for spacecraft and habitat design. Crucially, the calculation reveals a minimum dose equivalent value that cannot be reduced with added shielding, leaving mission duration as the only means of controlling accumulated dose equivalent so as to remain within recommended limits. In order to provide a benchmark set of experimental data that can be used to quantify the uncertainties in the calculations and provide some level of verification of their predictions, we have designed a series of experiments at the NASA Space Radiation Laboratory at Brookhaven National Laboratory to measure the light ion production created by GCR-like beams incident on a two-target system that mimics an enclosed, shielded environment. This paper gives detailed descriptions of the experimental configurations to provide accurate input data for transport models. Subsequent articles report the measurement results and comparisons to models.
Bibliographic Details
Provide Feedback
Have ideas for a new metric? Would you like to see something else here?Let us know