Heat Load for the ABC House
2023
- 208Usage
Metric Options: CountsSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Metrics Details
- Usage208
- Downloads160
- Abstract Views48
Thesis / Dissertation Description
Following the protocol set forth in the ASHRAE 2021 Fundamentals Handbook, this project modeled the heating load of the house for a design season (winter). This project reports the heating load calculation for a 1960 residential dwelling used as student housing in Swarthmore, PA. The infiltration, window, door, attic, 1st-3rd floor, and basement loads were found to be 5641 kW, 3239 kW, 273 kW, 262 kW, 4073 kW, and 514 kW respectively: resulting in a total design season heat load of 14001 kW. The three biggest contributors to the seasonal heat load were Infiltration, Window, and Wall load (40.3%, 29.1%, and 23.1% of total heat load respectively). Window and insulation replacement were the two most feasible reduction methods, with estimated installation costs of $16800 and ~$2,000 respectively. The following sections of this report include details on the methods used as well as a discussion of the load calculation and suggestion for heat load reduction.
Bibliographic Details
Provide Feedback
Have ideas for a new metric? Would you like to see something else here?Let us know