A performance study of multilevel physical field on pulsed electric fields
Vol: 32, Issue: 2, Page: 1-6
2016
- 14Usage
Metric Options: CountsSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Metrics Details
- Usage14
- Downloads14
Artifact Description
Pulsed electric field sterilization technology is one of the main concerned non-thermal sterilization technologies. One of its key components is treatment chamber, when the food material went the treatment chamber, in a very short period of time microorganisms endured strong electric field force, the cell structure was destructed, so the cell died. The electric field strength and the temperature distribution in the treatment chamber is the main factor of affecting the system bactericidal effect and food quality, the numerical simulation of the uid dynamics coupled with the electric and thermal eld inside the treatment chamber can provide detailed analysis. The main purpose of the numerical simulation is optimizing the geometry of the treatment chamber, thereby improving the uniformity of the electric field intensity and the temperature distribution, so avoiding the phenomenon such as localized over-processed or less processing and dielectric breakdown. This article reviews numerical investigations performed on the pulsed electric eld process and presents numerical results of a treatment chamber optimization and the solution of coupled uid dynamical, electrical and thermal problems.
Bibliographic Details
https://www.ifoodmm.cn/journal/vol32/iss2/1; https://www.ifoodmm.cn/cgi/viewcontent.cgi?article=3912&context=journal; http://dx.doi.org/10.13652/j.issn.1003-5788.2016.02.001; https://dx.doi.org/10.13652/j.issn.1003-5788.2016.02.001; https://www.chndoi.org/Resolution/Handler?doi=10.13652/j.issn.1003-5788.2016.02.001
Provide Feedback
Have ideas for a new metric? Would you like to see something else here?Let us know