Determination of bisphenol A in canned food by HPLC method
Vol: 32, Issue: 3, Page: 93-95
2016
- 35Usage
Metric Options: CountsSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Metrics Details
- Usage35
- Downloads28
- Abstract Views7
Artifact Description
The hollow fiber liquid phase microextraction high performance liquid chromatography (HF—LPME—HPLC) of bisphenol A in canned food were determined to establish a simple, fast and accurate detection method. Mainly use the two-phase hollow fiber (HF) of liquid phase microextraction (LPME) technology, combined with high performance liquid chromatography to the determination of bisphenol A (BPA) content, so as to realize the optimization of the extractant, sample solution pH, extraction temperature, extraction time and stirring rate and other basic data parameters optimization,The results of the study show that: to octanol as the extractant, the selection of the determination of food sample solution pH value of 6.1, and the corresponding extraction temperature is 40 degrees Celsius for 40 min, relative standard deviation was 4.3%. The detection limit was 12.7 g/L and bisphenol A in food sample enrichment times the number reached 200 times, the average sample recovery rate in between 86.1%~105%.
Bibliographic Details
https://www.ifoodmm.cn/journal/vol32/iss3/19; https://www.ifoodmm.cn/cgi/viewcontent.cgi?article=3984&context=journal; http://dx.doi.org/10.13652/j.issn.1003-5788.2016.03.019; https://dx.doi.org/10.13652/j.issn.1003-5788.2016.03.019; https://www.chndoi.org/Resolution/Handler?doi=10.13652/j.issn.1003-5788.2016.03.019
Provide Feedback
Have ideas for a new metric? Would you like to see something else here?Let us know