PlumX Metrics
Embed PlumX Metrics

Discussion on detection method of potassium permanganate consumption in hygienic standard of epoxy phenolic coatings for inner wall of food cans

Vol: 32, Issue: 6, Page: 58-60
2016
  • 0
    Citations
  • 27
    Usage
  • 0
    Captures
  • 0
    Mentions
  • 0
    Social Media
Metric Options:   Counts1 Year3 Year

Metrics Details

Artifact Description

The potassium permanganate consumption of the tin cans coated with epoxy phenolic coatings as the protective layer was detected according to the national standard of GB/T 5009.60-2003 method for analysis of hygienic standard of products of polyethylene, polystyrene and polypropyrene for food packaging. The method required accurate titer of potassium permanganate standard solution, and was not suitable for daily rapid detection. The test method adjusted the concentration of potassium permanganate solution and determined the value of f instead of the titration process of the standard solution. By the data analysis of two kinds of test conditions, the creditability and feasibility of the test method was ensured. The results showed that there was no significant difference between the test results and the national standard method results, and because of convenience and easy operation of the method,and the test method was more suitable for routine detection of enterprises.

Provide Feedback

Have ideas for a new metric? Would you like to see something else here?Let us know