Computational fluid dynamic simulation flow field and pressure drop characteristics of the gas-liquid two phase flow in a static spiral cutter
Vol: 34, Issue: 3, Page: 89-92
2018
- 24Usage
Metric Options: CountsSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Metrics Details
- Usage24
- Downloads24
Artifact Description
The internal oxygen-water two-phase flow in a static spiral cutter with special spiral structure was simulated employing ANSYS Fluent. The flow field and pressure drop characteristics inside the static spiral cutter was analyzed under different Reynolds numbers. The pressure dropping of gas-liquid two phase flow in the helical of cutter mixer showed an increase trend obviously with the increase of Reynolds number. The pressure dropping in the helical was larger than that in the horizontal circular straight tube. When Reynolds number changed from 800 to 26 000, the ratio of pressure of the spiral cutter to horizontal circular straight tube increased from 150 to 260.
Bibliographic Details
https://www.ifoodmm.cn/journal/vol34/iss3/19; https://www.ifoodmm.cn/cgi/viewcontent.cgi?article=2914&context=journal; http://dx.doi.org/10.13652/j.issn.1003-5788.2018.03.019; https://dx.doi.org/10.13652/j.issn.1003-5788.2018.03.019; https://www.chndoi.org/Resolution/Handler?doi=10.13652/j.issn.1003-5788.2018.03.019