Germicidal effects of ultraviolet on condensed milk barrel and its dynamic
Vol: 35, Issue: 4, Page: 108-112
2019
- 23Usage
Metric Options: CountsSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Metrics Details
- Usage23
- Downloads22
- Abstract Views1
Design Architecture Description
An innovation UV irradiation device was used to detect the germicidal efficacy of UV irradiation on microorganisms inside the condensed milk barrel. In terms of germicidal rates, experiments were conducted to investigate the disinfecting feasibility and the effectiveness of ultraviolet under 60 experimental conditions, which were formed by 4×5×3 factorial combinations of radiant intensity, radiant time and radiant distance. The results indicated the germicidal rate was positively correlated with the radiant intensity, radiant time and radiant distance. Meanwhile, it was up to 99.9% for 90 second by UV irradiation in the same light with the radiant intensity above 90 μW/cm2, when the initial consistence of bacteria in the barrel is about 104 CFU/cm2. It also showed the bacteria reaction order was among 1.00 and 1.04. The ultraviolet disinfection process can be viewed as first order kinetics of optical biochemistry. The first sterilization rate constant of bacteria equals to 0.34~0.37 cm2/(mW·s). The killing logarithm value was higher than 3.00. These results showed the device is effective in sterilizing.
Bibliographic Details
https://www.ifoodmm.cn/journal/vol35/iss4/21; https://www.ifoodmm.cn/cgi/viewcontent.cgi?article=2445&context=journal; http://dx.doi.org/10.13652/j.issn.1003-5788.2019.04.021; https://dx.doi.org/10.13652/j.issn.1003-5788.2019.04.021; https://www.chndoi.org/Resolution/Handler?doi=10.13652/j.issn.1003-5788.2019.04.021
Provide Feedback
Have ideas for a new metric? Would you like to see something else here?Let us know