Comparative study of electrospray mass spectrometry and first derivative method and validation by HPLC method
Journal of Food and Drug Analysis, Vol: 15, Issue: 2
2020
- 1Citations
- 94Usage
- 7Captures
Metric Options: Counts1 Year3 YearSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Metrics Details
- Citations1
- Citation Indexes1
- CrossRef1
- Usage94
- Downloads63
- Abstract Views31
- Captures7
- Readers7
Article Description
Three different methods are described for the simultaneous determination of amoxicillin trihydrate (AMX) and potassium klavulanate (KLV) in synthetic mixtures and pharmaceutical tablets. The first method depends on the first-derivative ultraviolet spectrophotometry with zero-crossing measurement. The second method is based on mass spectrometry utilizing electropspray ionization. For the electrospray studies in negative and positive ion modes, aspirin (ASP) and clindamycin (CLN) were used, respectively as internal standards for quantification. The calibration function was established in the same concentration ranges as in the first derivative method. A reversed-phase high performance liquid chromatographic (RP-HPLC) method involving ultraviolet detection (γ = 220 nm) was developed for the analysis of AMX and KLV. Chromatography was carried out on a C-18 column with mobile phase comprising of phosphate buffer-acetonitrile (40:60, v/v). The proposed methods have been validated with regard to the selectivity, detection limit, recovery, accuracy and precision. For both drugs, methods were found to be selective, linear (R ≈ 0.99), accurate (recovery = 100-105%) and precise (<3% RSD) in the range of 21-49 μg/mL for AMX and 3-7 μg/mL for KLV. The limit-of-detection and limit-of-quantification of the method were determined for three methods.
Bibliographic Details
The Journal of Food and Drug Analysis (JFDA), Food and Drug Administration, Taiwan (TFDA)
Provide Feedback
Have ideas for a new metric? Would you like to see something else here?Let us know