Development and validation of an ion-pair HPLC chromatography for simultaneous determination of lactone and carboxylate forms of SN-38 in nanoparticles
Journal of Food and Drug Analysis, Vol: 17, Issue: 4
2020
- 3Citations
- 433Usage
- 17Captures
Metric Options: Counts1 Year3 YearSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Metrics Details
- Citations3
- Citation Indexes3
- CrossRef3
- Usage433
- Downloads288
- Abstract Views145
- Captures17
- Readers17
- 17
Article Description
A simple and reproducible reversed-phase ion-pair high performance liquid chromatography (HPLC) method using isocratic elution with UV absorbance detection was developed and validated for the simultaneous determination of carboxylate (C) and lactone (L) forms of SN-38 (active metabolite of irinotecan) in nanoparticles (NPs). Reversed phase (RP) chromatography was performed on a C18 column with an ion-pair solution, KH2PO4 buffer solution and acetonitrile, under a mobile phase 30:30:40 (v/v) and at a flow rate of 1 mL/min. Detection was performed at 265 nm and sharp peaks were obtained for C and L forms of SN-38 at retention times of 2.9 ± 0.01 and 5.1 ± 0.01 min respectively. Linear regression analysis data for the calibration plot showed a good linear relationship between response and concentration in the range of 4 to 100 μg/mL; the regression coefficient was 0.9999 for L form and 0.9998 for C form. The optimized method showed good performance in terms of specificity, linearity, detection and quantitation limits, precision and accuracy in accordance with the International Conference on Harmonization (ICH) Q2 (R1) guidelines. This assay was demonstrated to be applicable for routine quantitation of SN-38 in PLGA NPs.
Bibliographic Details
The Journal of Food and Drug Analysis (JFDA), Food and Drug Administration, Taiwan (TFDA)
Provide Feedback
Have ideas for a new metric? Would you like to see something else here?Let us know