Viscosity Measurement of Newtonian Liquid Based on Ultrasonic Shear Wave Using Mode Conversion

Citation data:

Sensor Letters, ISSN: 1546-198X, Vol: 9, Issue: 4, Page: 1490-1495

Publication Year:
2011
Usage 2
Abstract Views 1
Link-outs 1
DOI:
10.1166/sl.2011.1659
Author(s):
Dong, Junliang, Cao, Li
Publisher(s):
American Scientific Publishers
Tags:
Engineering, Physics and Astronomy
article description
A method for viscosity measurement of Newtonian liquid using mode conversion from longitudinal wave to shear wave are presented in this paper. The Pspice electrical models for the simulation of the viscosity measurement system are established. An aluminum prism with an oblique solid-air interface converts the longitudinal wave to shear wave which is used to measure the liquid viscosity. Echo signals which obtain in the experiment are compared to the Pspice simulation results. By measuring the magnitude of the reflection coefficient alone in the frequency domain, we obtained the viscosity of Newtonian liquid with high accuracy which also fits the simulation results well. Copyright © 2011 American Scientific Publishers All rights reserved.

This article has 0 Wikipedia mention.