In-channel indirect amperometric detection of nonelectroactive anions for electrophoresis on a poly(dimethylsiloxane) microchip
Electrophoresis, ISSN: 0173-0835, Vol: 26, Issue: 19, Page: 3615-3621
2005
- 20Citations
- 11Captures
Metric Options: Counts1 Year3 YearSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Metrics Details
- Citations20
- Citation Indexes20
- 20
- CrossRef16
- Captures11
- Readers11
- 11
Article Description
In the present paper, we describe a microfluidics-based sensing system for non-electroactive anions under negative separation electric field by mounting a single carbon fiber disk working electrode (WE) in the end part of a poly(dimethylsiloxane) microchannel. In contrast to work in a positive separation electric field described in our previous paper (Anal. Chem. 2004, 76, 6902-6907), here the electrochemical reduction reaction at the WE is not coupled with the separation high-voltage (HV) system, whereas the electrochemical oxidation reaction at the WE is coupled with the separation HV system. The electroactive indicator is the carbon fiber WE itself but not dissolved oxygen. This provides a convenient and sensitive means for the determination of nonelectroactive anions by amperometry. The influences of separation voltage, detection potential, and the distance between the WE and the separation channel outlet on the response of the detector have been investigated. The present detection mode is successfully used to electrochemically detect F, CI, SO, CHCOO, HPO. Based on the preliminary results, a detection limit of 2 μM and a dynamic range up to three orders of magnitude for CI could be achieved. © 2005 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.
Bibliographic Details
http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=27244444681&origin=inward; http://dx.doi.org/10.1002/elps.200410401; http://www.ncbi.nlm.nih.gov/pubmed/16152662; https://onlinelibrary.wiley.com/doi/10.1002/elps.200410401; https://dx.doi.org/10.1002/elps.200410401; https://analyticalsciencejournals.onlinelibrary.wiley.com/doi/10.1002/elps.200410401
Wiley
Provide Feedback
Have ideas for a new metric? Would you like to see something else here?Let us know