Comparative investigation of bone mineral density using CT and DEXA in a canine femoral model
Journal of Orthopaedic Research, ISSN: 1554-527X, Vol: 35, Issue: 12, Page: 2667-2672
2017
- 9Citations
- 42Captures
Metric Options: CountsSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Metrics Details
- Citations9
- Citation Indexes9
- CrossRef8
- Captures42
- Readers42
- 42
Article Description
Bone density measurements using computed tomography (CT) instead of dual-energy X-ray absorptiometry (DEXA) are currently of great interest in human and veterinary medical research as it would be beneficial to use CT scans obtained for other indications also for determining bone density. For Hounsfield units (HU) measured with CT in specific regions of interests (ROIs) in one or several slice/s a correlation with bone mineral density (BMD) measured by DEXA in humans and dogs of between 0.44 and 0.77 is reported in the literature. In the present study, instead certain volumes of interest (VOIs) obtained by CT scan and the corresponding HU to the respective VOIs were compared with the bone mineral density of the corresponding areas measured by DEXA. The aim of the study was to investigate whether this procedure gives more accurate information about bone density of the bones as three-dimensional objects of the respective patient. Correlation between measured HU in the respective VOI and BMD measured with DEXA in the corresponding ROI showed a very good correlation of 0.93. Linear regression with R = 0.85 (p = 0.0262) was calculated. Except for VOI5, similar distribution of values and significant differences (p < 0.0001–0.0087) between ROIs/VOIs were detected. Determining HU for assessing bone mineral density in a certain volume provides more accurate results than those previously reported from two-dimensional (2D) CT measurements. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 35:2667–2672, 2017.
Bibliographic Details
Provide Feedback
Have ideas for a new metric? Would you like to see something else here?Let us know