B mapping by Bloch-Siegert shift
Magnetic Resonance in Medicine, ISSN: 1522-2594, Vol: 63, Issue: 5, Page: 1315-1322
2010
- 441Citations
- 532Captures
- 1Mentions
Metric Options: Counts1 Year3 YearSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Metrics Details
- Citations441
- Citation Indexes437
- 437
- CrossRef397
- Patent Family Citations4
- 4
- Captures532
- Readers532
- 532
- Mentions1
- References1
- 1
Article Description
A novel method for amplitude of radiofrequency field (B) mapping based on the Bloch-Siegert shift is presented. Unlike conventionally applied double-angle or other signal magnitude-based methods, it encodes the B information into signal phase, resulting in important advantages in terms of acquisition speed, accuracy, and robustness. The Bloch-Siegert frequency shift is caused by irradiating with an off-resonance radiofrequency pulse following conventional spin excitation. When applying the off-resonance radiofrequency in the kilohertz range, spin nutation can be neglected and the primarily observed effect is a spin precession frequency shift. This shift is proportional to the square of the magnitude of B . Adding gradient image encoding following the off-resonance pulse allows one to acquire spatially resolved B maps. The frequency shift from the Bloch-Siegert effect gives a phase shift in the image that is proportional to B. The phase difference of two acquisitions, with the radiofrequency pulse applied at two frequencies symmetrically around the water resonance, is used to eliminate undesired off-resonance effects due to amplitude of static field inhomogeneity and chemical shift. In vivo Bloch-Siegert B mapping with 25 sec/slice is demonstrated to be quantitatively comparable to a 21-min double-angle map. As such, this method enables robust, high-resolution Bmapping in a clinically acceptable time frame. © 2010 Wiley-Liss, Inc.
Bibliographic Details
Provide Feedback
Have ideas for a new metric? Would you like to see something else here?Let us know