Direct Signal Control of the steady-state response of 3D-FSE sequences
Magnetic Resonance in Medicine, ISSN: 1522-2594, Vol: 73, Issue: 3, Page: 951-963
2015
- 15Citations
- 56Captures
Metric Options: CountsSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Metrics Details
- Citations15
- Citation Indexes15
- 15
- CrossRef10
- Captures56
- Readers56
- 56
Article Description
Purpose: Parallel transmission (PTx) offers spatial control of radiofrequency (RF) fields that can be used to mitigate nonuniformity effects in high-field MRI. In practice, the ability to achieve uniform RF fields by static shimming is limited by the typically small number of channels. Thus, tailored RF pulses that mix gradient with RF encoding have been proposed. A complementary approach termed "Direct Signal Control" (DSC) is to dynamically update RF shims throughout a sequence, exploiting interactions between each pulse and the spin system to achieve uniform signal properties from potentially nonuniform fields. This work applied DSC to T2-weighted driven-equilibrium three-dimensional fast spin echo (3D-FSE) brain imaging at 3T. Theory and Methods: The DSC concept requires an accurate signal model, provided by extending the spatially resolved extended phase graph framework to include the steady-state response of driven-equilibrium sequences. An 8-channel PTx body coil was used for experiments. Results: Phantom experiments showed the model to be accurate to within 0.3% (root mean square error). In vivo imaging showed over two-fold improvement in signal homogeneity compared with quadrature excitation. Although the nonlinear optimization cannot guarantee a global optimum, significantly improved local solutions were found. Conclusion: DSC has been demonstrated for 3D-FSE brain imaging at 3T. The concept is generally applicable to higher field strengths and other anatomies.
Bibliographic Details
Provide Feedback
Have ideas for a new metric? Would you like to see something else here?Let us know