Design and Application of Controller Based on Sine-Cosine Algorithm for Load Frequency Control of Power System
Advances in Intelligent Systems and Computing, ISSN: 2194-5365, Vol: 941, Page: 301-311
2020
- 4Citations
- 7Captures
Metric Options: CountsSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Conference Paper Description
Load frequency control (LFC) has emerged as one of the potential research areas in the field of power system. LFC is a mechanism by which the system frequency is maintained within allowable limits by maintaining equilibrium between generation and load. In this study, design and application of controller based on sine-cosine algorithm (SCA) is utilized for LFC of interconnected power system. A proportional-integral-derivative (PID) controller with a filter consisting of derivative term is used and its parameters are tuned using SCA. The performance criterion chosen for tuning process is the minimization of integral error of variations in frequency and tie-line power. To examine the efficacy of SCA-PIDN controller, its performance is compared with other controllers reported in literature. Further, time-domain simulations are illustrated to support the obtained results. Additionally, the robustness of SCA-PIDN controller is examined with random load perturbations. The outcomes of the test cases reveal the superiority of SCA-PIDN controllers over others.
Bibliographic Details
http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=85065470975&origin=inward; http://dx.doi.org/10.1007/978-3-030-16660-1_30; http://link.springer.com/10.1007/978-3-030-16660-1_30; http://link.springer.com/content/pdf/10.1007/978-3-030-16660-1_30; https://dx.doi.org/10.1007/978-3-030-16660-1_30; https://link.springer.com/chapter/10.1007/978-3-030-16660-1_30