A new method of surgical tracking system based on fiducial marker
Communications in Computer and Information Science, ISSN: 1865-0929, Vol: 723, Page: 886-896
2017
- 3Citations
- 4Captures
Metric Options: CountsSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Conference Paper Description
Now used commercial surgical tracking devicessuch as near-infrared optical tracking system is ofcomplex system, non-multi-target tracking and weak anti-interference ability. A low-cost and accurate surgical tracking system based on the artificial markers was proposed in our study for the real-time tracking of surgical tools. Bumblebee2 binocular vision camera system is used to capturing pictures for stereo vision process. We adopt ARTag fiducial marker system in our tracking system. A robust and fast ARTag detecting algorithm is proposed and this edge based approach is proved to be fast and robust with the conducted experiments. A relative algorithm for the registration of surgical tools with the test boarder is also proposed to realize and test the tracking system. Experiments are conducted to test the performance of the tracking system. We judge the tracking accuracy by the error of the distance between two near corner points, and the tracking stability by the location error of the same corner point with different tool postures. Results show that the mean error of the distance between two adjacent corners points is 0.40 mm, mean error with stable tip of different marker rotation is 0.12 mm, which is comparable to the common used optical tracking system.
Bibliographic Details
http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=85023198803&origin=inward; http://dx.doi.org/10.1007/978-3-319-60964-5_77; http://link.springer.com/10.1007/978-3-319-60964-5_77; http://link.springer.com/content/pdf/10.1007/978-3-319-60964-5_77; https://dx.doi.org/10.1007/978-3-319-60964-5_77; https://link.springer.com/chapter/10.1007/978-3-319-60964-5_77