Combined use of positive and negative immunomagnetic isolation followed by real-time RT-PCR for detection of the circulating tumor cells in patients with colorectal cancers
Journal of Molecular Medicine, ISSN: 0946-2716, Vol: 82, Issue: 11, Page: 768-774
2004
- 44Citations
- 19Captures
Metric Options: Counts1 Year3 YearSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Metrics Details
- Citations44
- Citation Indexes43
- 43
- CrossRef22
- Policy Citations1
- 1
- Captures19
- Readers19
- 19
Article Description
To establish a novel molecular diagnostic method of detecting circulating tumor cells (CTCs) LS174T colon cancer cells were serially diluted with normal blood. Additional peripheral blood samples were collected from 25 patients with colorectal carcinoma. Mononuclear cells (MNCs) were collected, equally divided into four parts, and then cancer cells were enriched by four methods: method A, nonimmunobead method; method B, negative immunobead method: CD45 immunomagnetic beads were used to deplete the leukocytes; method C, positive immunobead method: Ber-EP4 immunomagnetic beads were used to enrich cancer cells; method D, negative-and-positive immunobead method: CD45 immunomagnetic beads were first used to deplete the leukocytes from MNC and then Ber-EP4 immunomagnetic beads were used to enrich cancer cells. Finally, real-time quantitative RT-PCR was used to monitor mRNA expression of β-mircoglobulin (β2M) and carcinoembryonic antigen (CEA). The relative CEA mRNA values were corrected with reference to β2M mRNA, to CEA mRNA/β2M mRNA ratios according to a CEA mRNA external standards prepared with tenfold serial dilutions (1-10 IS174T cells) of cDNA and β2M mRNA external standards prepared with tenfold serial dilutions (10-10 leukocytes) of cDNA. In recovery experiments a significant correlation between the number of cancer cells and CEA mRNA expression was found when CD45 or Ber-EP4 immunomagnetic beads were used alone. A highly significant correlation was found when CD45 and Ber-EP4 immunomagnetic beads were used successively. The sensitivity of method D was one cancer cell per milliliter of blood. Circulating cancer cells were detected in 19 of 25 patients with colorectal cancers. The relative CEA mRNA value obtained by method D was the smallest. The positive detection rate of circulating cancer cells in patients at Dukes' B, C, and D stages were 25.0% (1/ 4), 83.3% (10/12), and 88.9% (8/9). Combinative use of immunomagnetic isolation followed by real-time RT-PCR is a useful technique to detect circulating tumor cells in patients with colorectal carcinomas. Applying negative and positive immunomagnetic beads successively yields the highest correlation with amount of tumor cells. © Springer-Verlag 2004.
Bibliographic Details
http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=19944410126&origin=inward; http://dx.doi.org/10.1007/s00109-004-0590-8; http://www.ncbi.nlm.nih.gov/pubmed/15490093; http://link.springer.com/10.1007/s00109-004-0590-8; http://www.springerlink.com/index/10.1007/s00109-004-0590-8; http://www.springerlink.com/index/pdf/10.1007/s00109-004-0590-8; https://dx.doi.org/10.1007/s00109-004-0590-8; https://link.springer.com/article/10.1007/s00109-004-0590-8
Springer Science and Business Media LLC
Provide Feedback
Have ideas for a new metric? Would you like to see something else here?Let us know