Microquantification of inorganic and organic phosphate by negative ion electrospray tandem mass spectrometry
Analytical and Bioanalytical Chemistry, ISSN: 1618-2650, Vol: 407, Issue: 10, Page: 2933-2937
2015
- 4Citations
- 9Captures
Metric Options: CountsSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Article Description
Abstract A new method for inorganic phosphate microquantification is introduced based on negative ion electrospray tandem mass spectrometry and stable isotope dilution by 18O4-labeled phosphate. Quantification is performed using the non-labeled and 18O3-labeled [P18O3]- fragment ions at m/z 79 and 85, respectively, formed by dissociation of the [H2PO4]- ion at m/z 97 and 105, respectively, visible in negative ion electrospray ionization mass spectrometry (ESI-MS) spectra. Tandem mass spectrometry was selected to remove an overlap with the isobaric [HSO4]- ion at m/z 97 of sulfate and to establish an optimal sensitivity of the quantification assay. It is demonstrated that the assay can also measure the sum of inorganic and phosphoryl phosphate by prior enzymatic hydrolysis of phosphoryl phosphate. The assay works with phosphate concentrations in the micromolar range and, in combination with nano-ESI, is capable to quantitate absolute amounts of phosphate in the low nanogram range from complex samples.
Bibliographic Details
http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=84938081088&origin=inward; http://dx.doi.org/10.1007/s00216-015-8542-4; http://www.ncbi.nlm.nih.gov/pubmed/25709067; http://link.springer.com/10.1007/s00216-015-8542-4; https://dx.doi.org/10.1007/s00216-015-8542-4; https://link.springer.com/article/10.1007/s00216-015-8542-4