Aptasensor based on fluorescence resonance energy transfer for the determination of kanamycin
European Food Research and Technology, ISSN: 1438-2385, Vol: 248, Issue: 6, Page: 1563-1572
2022
- 9Citations
- 8Captures
Metric Options: CountsSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Article Description
Based on fluorescence resonance energy transfer, an ultrasensitive aptasensor was designed to detect kanamycin. Carbon quantum dots (CQDs) connected to the 3′ end of the hairpin aptamer (HP) acted as energy donor, while gold nanoparticles (AuNPs) bound to the 5′ end of HP acted as energy acceptor. The interaction due to the overlapping between absorption spectrum of AuNPs and emission spectrum of CQDs led to an obvious quenching. After adding kanamycin, the specific binding between target and HP made the HP structure change. Then, the distance between CQDs and AuNPs increased gradually, and fluorescence intensity would recover. Therefore, the recovery of fluorescence intensity can be used for kanamycin detection via optical responses. Under optimal conditions, fluorescence intensity had a good linear relationship with the logarithm of kanamycin concentration. The detection limit of kanamycin was 5.7 pM (3.22 × 10 μg/kg) and the detection concentration of kanamycin concentration was 0.01–500 nM (5.65 × 10–282.80 μg/kg). The aptasensor was also applied into the determination of kanamycin residues in milk.
Bibliographic Details
Springer Science and Business Media LLC
Provide Feedback
Have ideas for a new metric? Would you like to see something else here?Let us know