Biparametric MRI in prostate cancer during active surveillance: is it safe?
European Radiology, ISSN: 1432-1084, Vol: 34, Issue: 10, Page: 6217-6226
2024
- 3Citations
- 12Captures
- 2Mentions
Metric Options: CountsSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Metrics Details
- Citations3
- Citation Indexes3
- CrossRef2
- Captures12
- Readers12
- 12
- Mentions2
- News Mentions2
- 2
Most Recent News
New Prostate Cancer Study Findings Have Been Reported by Investigators at Cambridge University Hospitals NHS Foundation Trust (Biparametric Mri In Prostate Cancer During Active Surveillance: Is It Safe?)
2024 MAY 22 (NewsRx) -- By a News Reporter-Staff News Editor at Cancer Daily -- Fresh data on Oncology - Prostate Cancer are presented in
Review Description
Abstract: Active surveillance (AS) is the preferred option for patients presenting with low-intermediate-risk prostate cancer. MRI now plays a crucial role for baseline assessment and ongoing monitoring of AS. The Prostate Cancer Radiological Estimation of Change in Sequential Evaluation (PRECISE) recommendations aid radiological assessment of progression; however, current guidelines do not advise on MRI protocols nor on frequency. Biparametric (bp) imaging without contrast administration offers advantages such as reduced costs and increased throughput, with similar outcomes to multiparametric (mp) MRI shown in the biopsy naïve setting. In AS follow-up, the paradigm shifts from MRI lesion detection to assessment of progression, and patients have the further safety net of continuing clinical surveillance. As such, bpMRI may be appropriate in clinically stable patients on routine AS follow-up pathways; however, there is currently limited published evidence for this approach. It should be noted that mpMRI may be mandated in certain patients and potentially offers additional advantages, including improving image quality, new lesion detection, and staging accuracy. Recently developed AI solutions have enabled higher quality and faster scanning protocols, which may help mitigate against disadvantages of bpMRI. In this article, we explore the current role of MRI in AS and address the need for contrast-enhanced sequences. Clinical relevance statement: Active surveillance is the preferred plan for patients with lower-risk prostate cancer, and MRI plays a crucial role in patient selection and monitoring; however, current guidelines do not currently recommend how or when to perform MRI in follow-up. Key Points: Noncontrast biparametric MRI has reduced costs and increased throughput and may be appropriate for monitoring stable patients. Multiparametric MRI may be mandated in certain patients, and contrast potentially offers additional advantages. AI solutions enable higher quality, faster scanning protocols, and could mitigate the disadvantages of biparametric imaging.
Bibliographic Details
http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=85191170510&origin=inward; http://dx.doi.org/10.1007/s00330-024-10770-z; http://www.ncbi.nlm.nih.gov/pubmed/38656709; https://link.springer.com/10.1007/s00330-024-10770-z; https://dx.doi.org/10.1007/s00330-024-10770-z; https://link.springer.com/article/10.1007/s00330-024-10770-z