Simultaneous measurements of temperature and CO concentration employing diode laser absorption near 2.0 μm
Applied Physics B: Lasers and Optics, ISSN: 0946-2171, Vol: 118, Issue: 3, Page: 471-480
2015
- 16Citations
- 23Captures
Metric Options: CountsSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Article Description
Simultaneous measurements of gas temperature and CO concentration in combustion gases using an extended-wavelength diode laser sensor at 2.0 μm are reported. A CO transition pair located near 5,006.140 and 5,010.725 cm is selected based on existing line-selection criteria. The gas temperature and CO concentration are inferred from the peak heights of the 1f-normalized WMS-2f signals. Some important factors (modulation depth, total pressure, and species concentration) influencing the performance of the sensor are discussed. Validation experiments performed in a heated static cell indicated that the sensor has accuracies of 1.21 and 2.98 % for temperature and CO concentration measurement. The demonstration in combustion gases produced by a burner illustrates the potential of the 1f-normalized WMS-2f sensor for combustion diagnosis.
Bibliographic Details
http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=84922439627&origin=inward; http://dx.doi.org/10.1007/s00340-015-6015-2; http://link.springer.com/10.1007/s00340-015-6015-2; http://link.springer.com/content/pdf/10.1007/s00340-015-6015-2; http://link.springer.com/content/pdf/10.1007/s00340-015-6015-2.pdf; http://link.springer.com/article/10.1007/s00340-015-6015-2/fulltext.html; https://dx.doi.org/10.1007/s00340-015-6015-2; https://link.springer.com/article/10.1007/s00340-015-6015-2
Springer Science and Business Media LLC
Provide Feedback
Have ideas for a new metric? Would you like to see something else here?Let us know