Two-color frequency-multiplexed IMS technique for gas thermometry at elevated pressures
Applied Physics B: Lasers and Optics, ISSN: 0946-2171, Vol: 126, Issue: 3
2020
- 13Citations
- 21Captures
Metric Options: Counts1 Year3 YearSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Article Description
The development and demonstration of a high-bandwidth two-color temperature sensor for high-pressure environments using intensity-modulation spectroscopy (IMS) is presented. The sensor utilized rapid intensity modulation, beam coalignment, and frequency multiplexing to deal with common challenges for laser absorption spectroscopy systems at high pressures and achieved a sensor bandwidth of 100 kHz. The P(16) and R(6) transitions of the H O fundamental antisymmetric stretch rovibrational band near 2.5μm were chosen for initial development of this temperature diagnostic concept. Temperature validation experiments were conducted with shock tubes for both reactive and non-reactive environments. Shock tube experiments were first conducted with H O and N mixtures at pressures of around 8.2 atm, yielding temperature measurements with a standard deviation of 2.9K within the steady-state test time. The performance of this system was then validated at 36.9 atm, yielding temperature measurements with a standard deviation of 8.4K. By comparing the measured temperatures with calculated temperatures based on ideal shock jump relations, the sensor achieved an average accuracy within 4.3K of the known temperatures across multiple experiments spanning a range of 1030–1450 K, 8–38 atm. These results demonstrate that the IMS-based sensor enables high-precision measurements of temperature at high pressures.
Bibliographic Details
http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=85080989262&origin=inward; http://dx.doi.org/10.1007/s00340-020-7396-4; http://link.springer.com/10.1007/s00340-020-7396-4; http://link.springer.com/content/pdf/10.1007/s00340-020-7396-4.pdf; http://link.springer.com/article/10.1007/s00340-020-7396-4/fulltext.html; https://dx.doi.org/10.1007/s00340-020-7396-4; https://link.springer.com/article/10.1007/s00340-020-7396-4
Springer Science and Business Media LLC
Provide Feedback
Have ideas for a new metric? Would you like to see something else here?Let us know