A sensor arrangement optimization method for volumetric tomography: effective voxel correction maximization (EVCM)
Applied Physics B: Lasers and Optics, ISSN: 0946-2171, Vol: 128, Issue: 9
2022
- 4Citations
Metric Options: Counts1 Year3 YearSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Metrics Details
- Citations4
- Citation Indexes4
Article Description
This work reports the development and validation of a new imaging sensor arrangement optimization method for volumetric tomography, namely effective voxel corrections maximization (EVCM). Different from past optimization approaches that only studied the influence of sensor orientations on the reconstruction accuracy, the EVCM method considers the impact of both sensor orientations and measured target distribution. Combining all recorded target projections, the EVCM first determines the number of effective voxels, indicating the voxels that participate in tomographic calculation. The method then calculates the number of corrections that modifies the value of effective voxels within a single reconstruction iteration step. The ratio between numbers of corrections and effective voxels (R) is established as a new criterion for the sensor arrangement optimization to achieve improved reconstruction accuracy. Both numerical simulations on signal phantoms and controlled experiments on lab-scale flames are employed to validate the EVCM. Comparisons between EVCM and other sensor arrangement optimization methods are also performed based on the 3D reconstructions both numerically and experimentally. Results show that EVCM turns out to be a more accurate way to decide the optimal arrangements specified for different 3D targets.
Bibliographic Details
Springer Science and Business Media LLC
Provide Feedback
Have ideas for a new metric? Would you like to see something else here?Let us know