Potential advantages of an additional forearm rubber tourniquet in intravenous regional anesthesia: a randomized clinical trial
Journal of Anesthesia, ISSN: 1438-8359, Vol: 29, Issue: 4, Page: 551-556
2015
- 4Citations
- 35Captures
Metric Options: CountsSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Metrics Details
- Citations4
- Citation Indexes4
- CrossRef2
- Captures35
- Readers35
- 35
Article Description
Objective: Although the usefulness of an additional forearm tourniquet to conventional intravenous regional anesthesia (IVRA) has been reported, the forearm cuff may disturb the surgical field to some degree, especially in wrist surgery. In the present study, we assessed the clinical efficacy of a temporary additional forearm rubber tourniquet to the conventional upper arm tourniquet on the quality of IVRA. Methods: The study included 32 ASA physical status I and II adult patients undergoing elective hand surgery who were randomly allocated to either an additional forearm tourniquet group (Group F) or to a conventional upper arm tourniquet group (Group C). Upper arm tourniquet IVRA was established using 40 mL of 0.5 % lidocaine in Group C. Hypothetically enhanced forearm tourniquet IVRA was established using 10 mL of 0.5 % lidocaine with an additional forearm rubber tourniquet and then administering 30 mL of 0.25 % lidocaine after removing the forearm tourniquet in Group F. The sensory and motor block onset and recovery times, onset time of tourniquet pain, intraoperative fentanyl consumption, and incidence of local anesthetic toxicity were recorded. The numerical rating score (NRS) of perioperative and postoperative pain and quality of anesthesia were also assessed. Results: Although the total dose of lidocaine in Group F was less and the sensory and motor block onset times were significantly shorter in Group F than those in Group C (P < 0.05), there was no difference regarding sensory and motor block recovery times, onset time of tourniquet pain, intraoperative fentanyl consumption, NRS of perioperative and postoperative pain, and the quality of anesthesia in the two groups (P > 0.05). Compared with Group C, the incidence of local anesthetic toxicity (i.e., dizziness, 43.8 vs 6.2 %, P = 0.02) was significantly decreased in Group F. Conclusions: The combination of the additional forearm and upper arm tourniquets with a smaller amount of local anesthetic achieved more rapid onset of sensory and motor block, a similar quality of anesthesia and a lower incidence of local anesthetic toxicity compared with the conventional technique.
Bibliographic Details
http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=84939572981&origin=inward; http://dx.doi.org/10.1007/s00540-015-1988-x; http://www.ncbi.nlm.nih.gov/pubmed/25771759; http://link.springer.com/10.1007/s00540-015-1988-x; https://dx.doi.org/10.1007/s00540-015-1988-x; https://link.springer.com/article/10.1007/s00540-015-1988-x
Springer Science and Business Media LLC
Provide Feedback
Have ideas for a new metric? Would you like to see something else here?Let us know