Ex vivo and in vivo evaluation of transsphenoidal Liqoseal application to prevent cerebrospinal fluid leakage
Acta Neurochirurgica, ISSN: 0942-0940, Vol: 165, Issue: 6, Page: 1511-1521
2023
- 11Captures
Metric Options: CountsSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Metrics Details
- Captures11
- Readers11
- 11
Article Description
Background: Despite improvements in closure techniques by using a vital nasoseptal flap, the use of sealing materials, and improved neurosurgical techniques, cerebrospinal fluid (CSF) leak after transsphenoidal surgery still is a clinically relevant problem. Liqoseal® (Polyganics bv, Groningen, The Netherlands) is a CE-approved bioresorbable sealant patch for use as an adjunct to standard methods of cranial dural closure to prevent CSF leakage. This study aims to evaluate the application of Liqoseal in transsphenoidal surgery ex vivo and in vivo. Methods: 1. We created an ex vivo setup simulating the sphenoidal anatomy, using a fluid pump and porcine dura positioned on a conus with the anatomical dimensions of the sella to evaluate whether the burst pressure of Liqoseal applied to a bulging surface was above physiological intracranial pressure. Burst pressure was measured with a probe connected to dedicated computer software. Because of the challenging transsphenoidal environment, we tested in 4 groups with varying compression weight and time for the application of Liqoseal. 2. We subsequently describe the application of Liqoseal® in 3 patients during transsphenoidal procedures with intraoperative CSF leakage to prevent postoperative CSF leakage. Results: 1. Ex vivo: The overall mean burst pressure in the transsphenoidal setup was 231 (± 103) mmHg. There was no significant difference in mean burst pressure between groups based on application weight and time (p = 0.227). 2. In Vivo: None of the patients had a postoperative CSF leak. No nose passage problems were observed. One patient had a postoperative meningitis and ventriculitis, most likely related to preoperative extensive CSF leakage. Postoperative imaging did not show any local infection, swelling, or other device-related adverse effects. Conclusions: We assess the use of Liqoseal® to seal a dural defect during an endoscopic transsphenoidal procedure as to be likely safe and potentially effective.
Bibliographic Details
http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=85145985992&origin=inward; http://dx.doi.org/10.1007/s00701-022-05477-3; http://www.ncbi.nlm.nih.gov/pubmed/36624231; https://link.springer.com/10.1007/s00701-022-05477-3; https://dx.doi.org/10.1007/s00701-022-05477-3; https://link.springer.com/article/10.1007/s00701-022-05477-3