Monitoring of chemotherapy leukemia treatment using Raman spectroscopy and principal component analysis
Lasers in Medical Science, ISSN: 1435-604X, Vol: 29, Issue: 3, Page: 1241-1249
2014
- 56Citations
- 79Captures
Metric Options: Counts1 Year3 YearSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Metrics Details
- Citations56
- Citation Indexes56
- 56
- CrossRef19
- Captures79
- Readers79
- 79
Article Description
In this research, we used the Raman spectroscopy to distinguish between normal and leukemia blood serum and identify the different types of leukemia based on serum biochemistry. In addition, monitoring of patients under chemotherapy leukemia treatment (CHLT) was studied. Blood samples were obtained from seven patients who were clinically diagnosed with three leukemia types and 21 healthy volunteers. In addition, other five leukemia patients were monitored during the CHLT, two patients were declared healthy, one patient suspended it; the health of the other two patients worsened, and no improvement was observed along CHLT. The serum samples were put under an Olympus microscope integrated to the Raman system, and several points were chosen for the Raman measurement. The Horiba Jobin Yvon LabRAM HR800 Raman system is equipped with a liquid nitrogen-cooled detector and a laser of 830 nm with a power irradiation of 17 mW. It is shown that the serum samples from patient with leukemia and from the control group can be discriminated when multivariate statistical methods of principal component analysis (PCA) and linear discriminant analysis (LDA) are applied to their Raman spectra obtaining two large clusters corresponding to the control and leukemia serum samples and three clusters inside the leukemia group associated with the three leukemia types. The major differences between leukemia and control spectra were at 1,338 (Trp, α-helix, phospholipids), 1,447 (lipids), 1,523 (β-carotene), 1,556 (Trp), 1,587 (protein, Tyr), 1,603 (Tyr, Phe), and 1,654 (proteins, amide I, α-helix, phospholipids) cm, where these peaks were less intense in the leukemia spectrum. Minor differences occurred at 661 (glutathione), 890 (glutathione), 973 (glucosamine), 1,126 (protein, phospholipid C-C str), 1,160 (β-carotene), 1,174 (Trp, Phe), 1,208 (Trp), 1,246 (amide III), 1,380 (glucosamine), and 1,404 (glutathione) cm. Leukemia spectrum showed a peak at 917 cm associated with glutathione, but it was absent in the control spectrum. The results suggest that the Raman spectroscopy and PCA could be a technique with a strong potential of support for current techniques to detect and identify the different leukemia types by using a serum sample. Nevertheless, with the construction of a data library integrated with a large number of leukemia and control Raman spectra obtained from a wide range of healthy and leukemic population, the Raman-PCA technique could be converted into a new technique for minimally invasive real-time diagnosis of leukemia from serum samples. In addition, complementary results suggest that using these techniques is possible to monitor CHLT. © 2014 Springer-Verlag.
Bibliographic Details
http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=84902815499&origin=inward; http://dx.doi.org/10.1007/s10103-013-1515-y; http://www.ncbi.nlm.nih.gov/pubmed/24407964; http://link.springer.com/10.1007/s10103-013-1515-y; https://dx.doi.org/10.1007/s10103-013-1515-y; https://link.springer.com/article/10.1007/s10103-013-1515-y
Springer Science and Business Media LLC
Provide Feedback
Have ideas for a new metric? Would you like to see something else here?Let us know