Validation and Application of Molecularly Imprinted Polymers for SPE/UPLC–MS/MS Detection of Gemifloxacin Mesylate
Chromatographia, ISSN: 1612-1112, Vol: 82, Issue: 11, Page: 1617-1631
2019
- 9Citations
- 16Captures
Metric Options: Counts1 Year3 YearSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Article Description
Abstract: Eight molecularly imprinted polymers (MIPs) were synthesized for the determination of the antibacterial agent gemifloxacin mesylate (GFM). The polymers were prepared using GFM as a template, methacrylic acid (MAA) or 4-vinylpyridine (4-VP) as functional monomers, ethylene glycol dimethacrylate (EGDMA) as a cross linker, 2,2′-azobisisobutyronitrile (AIBN) as an initiator and a mixture of dimethylsulfoxide (DMSO)/acetonitrile (ACN) (1:1, v/v) as a porogen. The optimized polymer was utilized as a solid-phase extraction (SPE) sorbent material for GFM from different matrices. Different loading, washing and elution protocols were investigated. Quantitative analysis of the extracts was performed using a newly developed ultra-performance liquid chromatography–mass spectrometry (UPLC–MS/MS) method on an Acquity BEH C column (100 mm × 2.1 mm, particle size of 1.7 µm). The isocratic mobile phase was a mixture of methanol (MeOH)/water (HO) with 0.1% formic acid (70:30, v/v), the flow rate was 0.3 mL min and the column temperature was 40 °C. Lomefloxacin (LOM) was used as an internal standard. The developed method was validated based on the recommendations of the International Conference on Harmonization (ICH) and was found suitable for the extraction of GFM from a pharmaceutical drug preparation and spiked human urine samples. Recovery % values ranged from 90.24 to 112.8% with relative standard deviation (RSD) of less than 7%. Graphic Abstract: [Figure not available: see fulltext.].
Bibliographic Details
Springer Science and Business Media LLC
Provide Feedback
Have ideas for a new metric? Would you like to see something else here?Let us know