Multivariate Analysis of Perampanel in Pharmaceutical Formulations Using RP-HPLC
Chromatographia, ISSN: 1612-1112, Vol: 83, Issue: 11, Page: 1335-1343
2020
- 5Citations
- 7Captures
Metric Options: Counts1 Year3 YearSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Article Description
A new, sensitive, robust RP-HPLC method was developed using quality by design (QbD) approach for the determination of perampanel in pharmaceutical tablets. Screening of five independent factors; concentration and pH of the phosphate buffer, temperature, flow rate and % of the aqueous part of mobile phase; was performed by a fractional factorial design (FFD). Optimization of the significant variables was achieved numerically and graphically using response surface methodology. The Analysis was achieved on Hypersil BDS C (150 × 4.6 mm, 5 μm) column applying an isocratic mobile phase containing acetonitrile and phosphate buffer pH 3.9 (55.7:44.3; v/v) at 1.4 mL/min flow rate and an injection volume of 10 μL. The analyte was detected at 210 nm. The proposed method was validated according to ICH guidelines. A linear range of 5–200 μg/mL was obtained with a high correlation coefficient (R = 0.9999). The accuracy of the method ranged from 97.92 to 100.60% and the RSD was less than 1.5. The developed method was robust and showed high predictability.
Bibliographic Details
http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=85090861908&origin=inward; http://dx.doi.org/10.1007/s10337-020-03950-8; https://link.springer.com/10.1007/s10337-020-03950-8; https://link.springer.com/content/pdf/10.1007/s10337-020-03950-8.pdf; https://link.springer.com/article/10.1007/s10337-020-03950-8/fulltext.html; https://dx.doi.org/10.1007/s10337-020-03950-8; https://link.springer.com/article/10.1007/s10337-020-03950-8
Springer Science and Business Media LLC
Provide Feedback
Have ideas for a new metric? Would you like to see something else here?Let us know