Use of accumulation images obtained by arterial-phase contrast-enhanced harmonic grayscale ultrasonography to evaluate tumor vessels in focal nodular hyperplasia and other hepatic tumors
Journal of Medical Ultrasonics, ISSN: 1346-4523, Vol: 34, Issue: 1, Page: 3-10
2007
- 5Citations
- 4Captures
Metric Options: CountsSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Metrics Details
- Citations5
- Citation Indexes4
- CrossRef4
- Patent Family Citations1
- Patent Families1
- Captures4
- Readers4
Article Description
Purpose. To evaluate the usefulness of accumulation images obtained by arterial-phase contrast-enhanced harmonic grayscale ultrasonography for examining tumor vessels in focal nodular hyperplasia and other hepatic lesions. Methods. After injecting a galactose-palmitic acid contrast agent, we used conventional contrast-enhanced harmonic grayscale ultrasonography to scan 8 focal nodular hyperplasia lesions, 21 hepatocellular carcinomas, 2 cholangiocellular carcinomas, 12 hepatic metastases, 17 hemangiomas, and 2 angiomyolipomas. We then accumulated and superimposed consecutive conventional images (accumulation images) and compared them with corresponding conventional images to evaluate serial images of hepatic tumor vessels. Results. Serial tumor vessel findings obtained from accumulation images were superior to those obtained from conventional images in 51 (77%) of the 66 various hepatic lesions examined. Evidence of the spoke-wheel artery pattern in 2 of the 8 focal nodular hyperplasia lesions was equivocal in the conventional images, but accumulation images clearly depicted serial images of spoke-wheel arteries, clearly indicating a diagnosis of focal nodular hyperplasia. Accumulation images allowed the diagnosis of two additional focal nodular hyperplasia lesions that had not been correctly diagnosed as focal nodular hyperplasia from conventional images. Conclusion. Accumulation images obtained by arterial-phase contrast-enhanced harmonic grayscale ultrasonography are useful in evaluating hepatic tumor vessels, especially spoke-wheel arteries, which specifically indicate focal nodular hyperplasia. © 2007 The Japan Society of Ultrasonics in Medicine.
Bibliographic Details
http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=33947277748&origin=inward; http://dx.doi.org/10.1007/s10396-006-0132-9; http://www.ncbi.nlm.nih.gov/pubmed/27278173; http://link.springer.com/10.1007/s10396-006-0132-9; https://dx.doi.org/10.1007/s10396-006-0132-9; https://link.springer.com/article/10.1007/s10396-006-0132-9; http://www.springerlink.com/index/10.1007/s10396-006-0132-9; http://www.springerlink.com/index/pdf/10.1007/s10396-006-0132-9
Springer Science and Business Media LLC
Provide Feedback
Have ideas for a new metric? Would you like to see something else here?Let us know