Quality of virtual-non-contrast phases derived from arterial and delayed phases of fast-kVp switching dual-energy CT in patients after endovascular aortic repair
International Journal of Cardiovascular Imaging, ISSN: 1875-8312, Vol: 39, Issue: 9, Page: 1805-1813
2023
- 6Citations
- 2Captures
Metric Options: Counts1 Year3 YearSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Metrics Details
- Citations6
- Citation Indexes6
- Captures2
- Readers2
Article Description
Objective of this study is: to analyze CT numbers in arteries and endoleaks in true non-contrast (TNC) and virtual non-contrast phases derived from arterial (VNCa) and delayed (VNCd) phases of dual-energy CT (DECT) in patients after endovascular aneurysm repair (EVAR); to assess the impact of image noise on subjective image quality parameters and the degree of subtraction of calcifications; to calculate effective dose (ED) reduction following replacement of TNC with VNC. The study included 97 patients after EVAR procedure. An initial single-energy TNC acquisition was followed by two DECT acquisitions. CT numbers of TNC, VNCa, VNCd were analyzed statistically. VNCd images were assessed qualitatively. The mean densities in endoleaks were 46.19 HU in TNC, 51.24 HU in VNCa, 42.24 HU in VNCd. The differences between them were statistically significant (p < 0.05). The mean signal-to-noise ratio (SNR) measured in the aorta and endoleaks was highest in VNCa, lowest in TNC images. No correlation between image noise, the results of qualitative analysis of VNCd, and the degree of subtraction of calcifications was found. Omitting TNC led to mean 6.54 ± 1.63 (SD) mSv (23.28% of total examination) ED reduction. VNC images have a higher SNR compared to TNC images with significant differences in the CT numbers between the TNC and VNC reconstructions. Image noise has no impact on the subjective image quality and the degree of subtraction of calcifications in VNCd images. The findings show a high diagnostic value of VNC images and suggest that VNCd images are optimal in the assessment of endoleaks with possible substantial ED reduction.
Bibliographic Details
http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=85161885695&origin=inward; http://dx.doi.org/10.1007/s10554-023-02887-x; http://www.ncbi.nlm.nih.gov/pubmed/37314532; https://link.springer.com/10.1007/s10554-023-02887-x; https://dx.doi.org/10.1007/s10554-023-02887-x; https://link.springer.com/article/10.1007/s10554-023-02887-x
Springer Science and Business Media LLC
Provide Feedback