Parameter Study on Double-row Pile in the Combined High Retaining Structure
Geotechnical and Geological Engineering, ISSN: 1573-1529, Vol: 40, Issue: 10, Page: 5233-5248
2022
- 4Citations
- 3Captures
Metric Options: Counts1 Year3 YearSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Article Description
The combined high retaining structure with little urban space, especially under the deep under-consolidated earth filling condition, was studied based on the project in Liangmao mountain depot of Shenzhen Metro Line 10. The superiority of the combined retaining structure including double-row piles over the pile-slab wall, single-row piles, and gravity retaining wall schemes was confirmed based on the numerical analysis by MIDAS/GTS. Based on the this, the force and deformation characteristics, including the influence of pile diameter, row spacing, and pile length on the displacement and internal force of the retaining structure, were analyzed. The simulation results show that the change of the pile diameter has a great influence on the displacement and the bending moment of the pile. As the row spacing increases, the absolute value of the maximum negative bending moment in the upper part of the front row of piles and the positive bending moment in the lower part tends to decrease. The pile length has some influence on the horizontal displacement of the pile but only a limited influence on the internal force of the pile.
Bibliographic Details
Springer Science and Business Media LLC
Provide Feedback
Have ideas for a new metric? Would you like to see something else here?Let us know