Highly sensitive and wide linearity flexible pressure sensor with randomly distributed columnar arrays
Journal of Materials Science, ISSN: 1573-4803, Vol: 58, Issue: 8, Page: 3735-3751
2023
- 13Citations
- 5Captures
Metric Options: Counts1 Year3 YearSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Article Description
Flexible pressure sensors with high sensitivity and a wide linear pressure response range have great potential in human health monitoring and robotics. Nevertheless, the performance and control of flexile sensors with specialized microstructures need to be enhanced. This work constructed a normal randomly distributed columnar array with a flexible interdigital electrode as the active layer. The array was prepared by aerosol printing instead of the traditional inversion method. This enabled effective control of the columnar array structure. Sandpaper inversion was used to fabricate the contact layer of a film consisting of Ecoflex00-30 and multi-walled carbon nanotubes, forming a bilayer contact resistive structure. The interlocking flexible pressure sensor was packaged and simplified into two layers. Experimental results show that the designed flexible pressure sensor has a high sensitivity of 38.25 kPa, fast response time of 43 ms, and relaxation time of 49 ms. Meanwhile, the stability was excellent over a wide linear range from 0 to 128 kPa. The sensor also performs satisfactorily in monitoring physiological health signals such as human pulse and sound vibration. Graphical Abstract: [Figure not available: see fulltext.].
Bibliographic Details
Springer Science and Business Media LLC
Provide Feedback
Have ideas for a new metric? Would you like to see something else here?Let us know