Predicting fluid responsiveness in whom? A simulated example of patient spectrum influencing the receiver operating characteristics curve
Journal of Clinical Monitoring and Computing, ISSN: 1573-2614, Vol: 32, Issue: 2, Page: 215-219
2018
- 2Citations
- 10Captures
- 1Mentions
Metric Options: Counts1 Year3 YearSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Metrics Details
- Citations2
- Citation Indexes2
- CrossRef2
- Captures10
- Readers10
- Mentions1
- News Mentions1
- News1
Most Recent News
Predicting fluid responsiveness in whom? A simulated example of patient spectrum influencing the receiver operating characteristics curve.
Journal of clinical monitoring and computing 2017 04 21() doi 10.1007/s10877-017-0019-x Abstract The influence of patient spectrum on the sensitivities and specificities of diagnostic methods
Article Description
The influence of patient spectrum on the sensitivities and specificities of diagnostic methods has been termed spectrum bias or spectrum effect. Receiver operating characteristics curves are often used to assess the ability of diagnostic methods to predict fluid responsiveness. As a receiver operating characteristics curve is a presentation of sensitivity and specificity, the purpose of the present manuscript was to explore if patient spectrum could affect areas under receiver operating characteristics curves and their gray zones. Relationships between stroke volume variation and change in stroke volume in two different patient populations using simulated data. Simulated patient populations with stroke volume variation values between 5 and 15 or 3 and 25% had median (2.5th–97.5th percentiles) areas under receiver operating characteristics curves of 0.79 (0.65–0.90) and 0.93 (0.85–0.99), respectively. The gray zones indicating range of diagnostic uncertainty were also affected. The patient spectrum can affect common statistics from receiver operating characteristics curves, indicating the need for considering patient spectrum when evaluating the abilities of different methods to predict fluid responsiveness.
Bibliographic Details
http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=85018821127&origin=inward; http://dx.doi.org/10.1007/s10877-017-0019-x; http://www.ncbi.nlm.nih.gov/pubmed/28432561; http://link.springer.com/10.1007/s10877-017-0019-x; https://dx.doi.org/10.1007/s10877-017-0019-x; https://link.springer.com/article/10.1007/s10877-017-0019-x
Springer Science and Business Media LLC
Provide Feedback
Have ideas for a new metric? Would you like to see something else here?Let us know