Non-invasive electrical cardiometry cardiac output monitoring during prehospital helicopter emergency medical care: a feasibility study
Journal of Clinical Monitoring and Computing, ISSN: 1573-2614, Vol: 36, Issue: 2, Page: 363-370
2022
- 2Citations
- 17Captures
Metric Options: Counts1 Year3 YearSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Metrics Details
- Citations2
- Citation Indexes2
- CrossRef2
- Captures17
- Readers17
- 17
Article Description
Purpose: Introducing advanced hemodynamic monitoring might be beneficial during Helicopter Emergency Medical Service (HEMS) care. However, it should not increase the on-scene-time, it should be easy to use and should be non-invasive. The goal of this study was to investigate the feasibility of non-invasive cardiac output measurements by electrical cardiometry (EC) and the quality of the EC signal during pre-hospital care provided by our HEMS. Methods: A convenience sample of fifty patients who required HEMS assistance were included in this study. Problems with respect to connecting the patient, entering patient characteristics and measuring were inventoried. Quality of EC signal of the measurements was assessed during prehospital helicopter care. We recorded the number of measurements with a signal quality indicator (SQI) ≥ 80 and the number of patients having at least 1 measurement with a SQI ≥ 80. Furthermore, the SQI value distribution of the measurements within each patient was analysed. Results: In the experience of the attending HEMS caregivers application of the device was easy and did not result in increased duration of on-scene time. Patch adhesion was reported as a concern due to clammy skin in 22% of all cases. 684 measurements were recorded during HEMS care. In 47 (94%) patients at least 1 measurement with an SQI ≥ 80 was registered. Of all recorded measurements 5.8% had an SQI < 40, 11.4% had an SQI 40–59, 14.9% had a SQI between 60 and 79 and 67.8% had SQI ≥ 80. Conclusion: Cardiac output measurements are feasible during prehospital HEMS care with good quality of the EC signal. Monitoring was easy to use and quick to install. In our view it is an promising candidate for the prehospital setting. Further research is needed to determine its clinical value during clinical decision making.
Bibliographic Details
http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=85099773541&origin=inward; http://dx.doi.org/10.1007/s10877-021-00657-5; http://www.ncbi.nlm.nih.gov/pubmed/33486570; https://link.springer.com/10.1007/s10877-021-00657-5; https://dx.doi.org/10.1007/s10877-021-00657-5; https://link.springer.com/article/10.1007/s10877-021-00657-5
Springer Science and Business Media LLC
Provide Feedback
Have ideas for a new metric? Would you like to see something else here?Let us know