Radio Frequency Identification Gate System to Identify Misused Personal Dosimeters
Journal of Medical Systems, ISSN: 1573-689X, Vol: 47, Issue: 1, Page: 107
2023
- 1Captures
- 1Mentions
Metric Options: Counts1 Year3 YearSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Metrics Details
- Captures1
- Readers1
- Mentions1
- News Mentions1
- 1
Most Recent News
Radio Frequency Identification Gate System to Identify Misused Personal Dosimeters. Tamura M, Kawamoto T, Ishifuro M, Tamura T, Masumoto Y, Kenjo M, Kiguchi M, Awai K, Nagata Y, J Med Syst 2023; 47 (1): 107
By: Tamura M, Kawamoto T, Ishifuro M, Tamura T, Masumoto Y, Kenjo M, Kiguchi M, Awai K, Nagata Y Published in: J Med Syst 2023;
Article Description
The use of two personal dosimeters, one worn over and one worn under a protective apron, provides the best estimate of effective dose. However, inappropriate positioning of dosimeters is a common occurrence, resulting in abnormally high or low radiation exposure records. Although such incorrect positioning can be identified by radiation exposure records, doing so is time-consuming and labor-intensive for administrators. Therefore, a system that can identify incorrect locations of dosimeters without burdening administrators must be developed. In this study, we developed a radio frequency identification (RFID) gate system that can differentiate between two RFID-tagged dosimeters placed over and under a metal apron and identify misused dosimeters. To simulate the position of the RFID-tagged dosimeters, we designed four dosimeter-wearing classes, including “proper use” and three types of “misuse” (i.e., “reversed,” “both under,” and “both over”). When the system predicts “misuse” based on the tag reading, the worker is alerted with lights and alarms. The system performance was evaluated using a confusion matrix, with an overall accuracy of 97.75%, demonstrating high classification performance. The safety of the system against life support devices was also investigated, demonstrating that they were not affected by the electric field at 0.3 m or more from the antenna of the system under any transmit powers tested. This RFID gate system is highly capable of identifying incorrectly positioned dosimeters, enabling real-time monitoring of dosimeters to manage their positioning.
Bibliographic Details
http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=85174467746&origin=inward; http://dx.doi.org/10.1007/s10916-023-02002-6; http://www.ncbi.nlm.nih.gov/pubmed/37851155; https://link.springer.com/10.1007/s10916-023-02002-6; https://dx.doi.org/10.1007/s10916-023-02002-6; https://link.springer.com/article/10.1007/s10916-023-02002-6