Determination of ultratrace amounts of plutonium in high saline groundwater by inductively coupled plasma mass spectrometry
Journal of Radioanalytical and Nuclear Chemistry, ISSN: 1588-2780, Vol: 298, Issue: 1, Page: 111-117
2013
- 3Citations
- 7Captures
Metric Options: Counts1 Year3 YearSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Article Description
For determination of ultratrace amounts of plutonium in high saline groundwater, large-volume sampling and preconcentration are necessary. However, traditional co-precipitation methods, such as Fe(OH), Ca(OH) -Mg(OH) and hydroxide-carbonate co-precipitation, are unable to meet the requirements of preconcentration of the ultratrace plutonium in high saline groundwater. In this paper, the ultratrace plutonium in high saline groundwater was concentrated by sequential co-precipitation with MnO and Fe(OH), and purified by two-stage anion-exchange separation on Dowex1 × 4 resin column. Quadrupole ICP-MS was employed for the determination of Pu with Pu spiked. After co-precipitation and purification, the major matrix elements were significantly decreased to μg mL level and decontamination factor of uranium is better than 10. The detection limit for Pu in 50 L high saline water is 2.1 × 10 g L. Three high saline fountain samples (total dissolved solids more than 20 g L) from Dunhuang region of China were analyzed using this method. The concentrations of Pu in these samples were 0.48 ± 0.2 × 10, 1.40 ± 0.10 × 10 and 2.13 ± 0.21 × 10 g L respectively. The recovery obtained for 7 pg of Pu spiked into real high saline-water samples was all above 70 %. © 2013 Akadémiai Kiadó, Budapest, Hungary.
Bibliographic Details
Springer Science and Business Media LLC
Provide Feedback
Have ideas for a new metric? Would you like to see something else here?Let us know