Cardiac point-of-care to cart-based ultrasound translation using constrained CycleGAN
International Journal of Computer Assisted Radiology and Surgery, ISSN: 1861-6429, Vol: 15, Issue: 5, Page: 877-886
2020
- 23Citations
- 50Captures
Metric Options: Counts1 Year3 YearSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Metrics Details
- Citations23
- Citation Indexes23
- 23
- CrossRef5
- Captures50
- Readers50
- 50
Article Description
Purpose: The emerging market of cardiac handheld ultrasound (US) is on the rise. Despite the advantages in ease of access and the lower cost, a gap in image quality can still be observed between the echocardiography (echo) data captured by point-of-care ultrasound (POCUS) compared to conventional cart-based US, which limits the further adaptation of POCUS. In this work, we aim to present a machine learning solution based on recent advances in adversarial training to investigate the feasibility of translating POCUS echo images to the quality level of high-end cart-based US systems. Methods: We propose a constrained cycle-consistent generative adversarial architecture for unpaired translation of cardiac POCUS to cart-based US data. We impose a structured shape-wise regularization via a critic segmentation network to preserve the underlying shape of the heart during quality translation. The proposed deep transfer model is constrained to the anatomy of the left ventricle (LV) in apical two-chamber (AP2) echo views. Results: A total of 1089 echo studies from 841 patients are used in this study. The AP2 frames are captured by POCUS (Philips Lumify and Clarius) and cart-based (Philips iE33 and Vivid E9) US machines. The dataset of quality translation comprises a total of 441 echo studies from 395 patients. Data from both POCUS and cart-based systems of the same patient were available in 122 cases. The deep-quality transfer model is integrated into a pipeline for an automated cardiac evaluation task, namely segmentation of LV in AP2 view. By transferring the low-quality POCUS data to the cart-based US, a significant average improvement of 30% and 34 mm is obtained in the LV segmentation Dice score and Hausdorff distance metrics, respectively. Conclusion: This paper presents the feasibility of a machine learning solution to transform the image quality of POCUS data to that of high-quality high-end cart-based systems. The experiments show that by leveraging the quality translation through the proposed constrained adversarial training, the accuracy of automatic segmentation with POCUS data could be improved.
Bibliographic Details
http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=85084083256&origin=inward; http://dx.doi.org/10.1007/s11548-020-02141-y; http://www.ncbi.nlm.nih.gov/pubmed/32314226; https://link.springer.com/10.1007/s11548-020-02141-y; https://dx.doi.org/10.1007/s11548-020-02141-y; https://link.springer.com/article/10.1007/s11548-020-02141-y
Springer Science and Business Media LLC
Provide Feedback
Have ideas for a new metric? Would you like to see something else here?Let us know