An improved differential algorithm for the critical-angle refractometer
Optoelectronics Letters, ISSN: 1993-5013, Vol: 15, Issue: 2, Page: 108-112
2019
- 2Citations
- 1Captures
Metric Options: CountsSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Letter Description
Due to the limit of the pixel size of the charge-coupled device (CCD) or complementary metal oxide semiconductor (CMOS) sensor, the traditional differential algorithm has a limited measuring accuracy by determining the critical angle in integral pixel. In this paper, we present a practical algorithm based on the centroid value of the reflective ratio around the critical angle pixel to address the traditional differential algorithm problem of determining the critical angle under sub-pixel in a critical angle refractometer (CAR). When the change of refractive index (RI) of a liquid sample is beyond the sensitivity of the traditional differential algorithm, the RI of the liquid can be obtained by using the centroid value of reflectivity around the critical angle pixel. The centroid value is associated with the RI change of the liquid in sub-pixel. Demonstrated by both theoretical analyses and experimental results using saline solutions with RI that changes in sub-pixel tested through the reflective CAR, the algorithm is found to be computationally effective and robust to expand the measuring accuracy of the Abbe-type refractometer in sub-pixel.
Bibliographic Details
http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=85065170470&origin=inward; http://dx.doi.org/10.1007/s11801-019-8137-y; http://link.springer.com/10.1007/s11801-019-8137-y; http://link.springer.com/content/pdf/10.1007/s11801-019-8137-y.pdf; http://link.springer.com/article/10.1007/s11801-019-8137-y/fulltext.html; https://dx.doi.org/10.1007/s11801-019-8137-y; https://link.springer.com/article/10.1007/s11801-019-8137-y
Springer Science and Business Media LLC
Provide Feedback
Have ideas for a new metric? Would you like to see something else here?Let us know