Left-ventricular dyssynchrony in viable myocardium by myocardial perfusion SPECT is predictive of mechanical response to CRT
Annals of Nuclear Medicine, ISSN: 1864-6433, Vol: 35, Issue: 8, Page: 947-954
2021
- 5Citations
- 13Usage
- 11Captures
Metric Options: Counts1 Year3 YearSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Metrics Details
- Citations5
- Citation Indexes5
- Usage13
- Abstract Views13
- Captures11
- Readers11
- 11
Article Description
Objectives: Gated myocardial perfusion SPECT (GMPS) provides a one-stop-shop evaluation for cardiac resynchronization therapy (CRT). However, conflicting results have been observed regarding whether the baseline left-ventricular (LV) mechanical dyssynchrony as assessed by phase analysis on GMPS was predictive of therapeutic response to CRT. Since dyssynchrony parameters by phase analysis spuriously increased by scarred myocardium, the purpose of this study was to explore the value of dyssynchrony after stripping off the scar region in correlation to mechanical response to CRT. Methods: Forty-seven patients following standard indications for CRT received GMPS with phase analysis as pre-CRT evaluation. A decrease of end-systolic volume (ESV) > 15% on follow-up echocardiography after CRT was considered as a mechanical response to CRT. Myocardial regions with less than 50% of maximal activity on GMPS were considered as a scar. The phase standard deviation (PSD) and histogram bandwidth (BW) without or with stripping off scar were assessed by phase analysis of GMPS and were used for evaluation of LV dyssynchrony of all myocardium or only the viable myocardium, respectively. Results: No significant difference was noted between mechanical responders (31 of 47 patients, 66%) and nonresponders (16 of 47 patients, 34%) for PSD (48.6° ± 19.4° vs 43.9° ± 20.7°, p = 0.46) and BW (225° ± 91.1° vs 163.5° ± 94.6°, p = 0.38) of the entire myocardium. However, responders had significantly larger PSD (40.5° ± 15.7° vs 30.5° ± 13.2°, p = 0.03) and borderlinely larger BW (215° ± 91.2° vs. 139.5° ± 78.2°, p = 0.05) than non-responders after stripping off scar. Logistic regression analysis showed that scar area and PSD after stripping off scar were independent predictors of mechanical response. Conclusions: Our result showed that LV dyssynchrony of the entire myocardium did not predict response to CRT. However, LV dyssynchrony only in the viable myocardium was a significant predictor of CRT mechanical response.
Bibliographic Details
http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=85106286988&origin=inward; http://dx.doi.org/10.1007/s12149-021-01632-5; http://www.ncbi.nlm.nih.gov/pubmed/34021491; https://link.springer.com/10.1007/s12149-021-01632-5; https://digitalcommons.mtu.edu/michigantech-p/14934; https://digitalcommons.mtu.edu/cgi/viewcontent.cgi?article=34236&context=michigantech-p; https://dx.doi.org/10.1007/s12149-021-01632-5; https://link.springer.com/article/10.1007/s12149-021-01632-5
Springer Science and Business Media LLC
Provide Feedback
Have ideas for a new metric? Would you like to see something else here?Let us know