Comparison of Rapid Centrifugation Technique with Conventional Centrifugation for Prothrombin Time (PT) and Activated Partial Thromboplastin Time (APTT) Testing
Indian Journal of Hematology and Blood Transfusion, ISSN: 0974-0449, Vol: 35, Issue: 1, Page: 161-166
2019
- 4Citations
- 19Captures
Metric Options: Counts1 Year3 YearSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Metrics Details
- Citations4
- Citation Indexes4
- CrossRef1
- Captures19
- Readers19
- 19
Article Description
Prothrombin Time (PT) and activated partial thromboplastin time (APTT) are frequently performed coagulation tests in patients with coagulation disorders especially in critical care areas and in monitoring patients on anticoagulation therapy. In coagulation testing, sample processing especially centrifugation is one of the most critical steps that affect turnaround time (TAT). This study was carried out over a period of 1 year. Three hundred paired samples from patients sent for PT and APTT estimation were included. One sample was centrifuged in a regular bench top centrifuge at 1500g for 20 min. The other sample was divided into two polypropylene aliquots and centrifuged in a microcentrifuge at 13000g for 3 min. The plasma obtained from both methods was tested for PT and APTT using the automated method on STA Compact coagulometer (Stago) using commercial thromboplastin STA -Neoplastine C1 Plus and phospholipid (cephalin), STA -C K PREST 5 respectively. Data were analyzed using descriptive statistics, Student t test, correlation coefficient and Bland–Altman plots. Mean PT, INR and APTT for both centrifugation methods was comparable with no statistically significant difference (p > 0.05). PT, INR and APTT also showed good correlation (r > 0.98) when compared between the two methods of centrifugation. Bland–Altman comparison between rapid and conventional methods of centrifugation for PT, INR and APTT also showed acceptable agreement. Rapid centrifugation technique for routine coagulation testing can be used safely with a significant reduction in the TAT. This can benefit patients in critical care settings and those on outpatient oral anticoagulant therapy.
Bibliographic Details
http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=85050002904&origin=inward; http://dx.doi.org/10.1007/s12288-018-0983-4; http://www.ncbi.nlm.nih.gov/pubmed/30828165; http://link.springer.com/10.1007/s12288-018-0983-4; https://dx.doi.org/10.1007/s12288-018-0983-4; https://link.springer.com/article/10.1007/s12288-018-0983-4
Springer Science and Business Media LLC
Provide Feedback
Have ideas for a new metric? Would you like to see something else here?Let us know