Estimation of the performance of different pumps using non-Newtonian fluids in various operating conditions with artificial neural network
Arabian Journal for Science and Engineering, ISSN: 2191-4281, Vol: 49, Issue: 11, Page: 14607-14623
2024
- 4Captures
Metric Options: Counts1 Year3 YearSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Metrics Details
- Captures4
- Readers4
Article Description
The performance of three centrifugal pumps designed to operate at a rotational speed of 151.84 rad/s and flow rates of 1, 25, and 45 kg/s is being investigated for both water and non-Newtonian fluids at various rotational speeds and flow rates. The analyses are being conducted experimentally and numerically within the flow rate range of 0.25–55 kg/s and rotational speed values between 52.36 and 151.84 rad/s. Additionally, artificial neural networks (ANN) trained using experimental pump performance data are being tested with experimental and numerical values obtained at a new rotational speed of 130.9 rad/s. The non-Newtonian fluids being tested include CMC 0.2% and CMC 0.4%, comprising carboxy methyl cellulose (CMC) solution and water. The results indicate that the pump's performance when handling non-Newtonian fluids is significantly influenced by the pump's geometry, rotational speed, and flow rate. In design parameters, the head obtained with 0.2% CMC for pump 1 is 3.3% greater than that in water. For pump 2, the highest head is in water according to design parameters. Pump 3 exhibits the highest head at a CMC of 0.4 in design parameters, and this value is 0.81% higher than the value with water. Experimental and numerical results demonstrate good agreement, especially in design parameters. The head obtained from numerical analyses with the RNG k–ε turbulence model for pumps 1, 2, and 3 at design parameters is 3, 10, and 9.83 m, respectively. The corresponding experimental heads are 3, 10, and 9.84 m, respectively. However, discrepancies between these results increase with higher flow rates and the use of non-Newtonian fluids. The compatibility of ANN results with experimental results is better than with numerical results, particularly at higher flow rates than the design condition. Pump performance values estimated by ANNs are 2% lower than the experimental results. This study provides comprehensive experimental data on the use of non-Newtonian fluids in different centrifugal pumps, and it also offers important guidance for future research by comparing ANN and computational fluid dynamics.
Bibliographic Details
Springer Science and Business Media LLC
Provide Feedback
Have ideas for a new metric? Would you like to see something else here?Let us know