Development and evaluation of selective coating for stir bar sorptive extraction of silver using sol-gel technique in combination with double-imprinting concept
Journal of the Iranian Chemical Society, ISSN: 1735-2428, Vol: 12, Issue: 6, Page: 929-936
2015
- 9Citations
- 11Captures
Metric Options: CountsSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Article Description
Abstract The flexibility and simplicity of stir bar sorption extraction (SBSE) have been combined with the selectivity of ion imprinted polymers (IIP) and a selective and fast extraction and preconcentration method for Ag(I) has been developed. The stir bar was coated with silver imprinted polymer using sol-gel technique in combination with double-imprinting concept. The retained silver was eluted with 250 μL thiourea solution (0.5 mol L-1) at a pH of 3.0-4.0 and was determined by flow injection-flame atomic absorption spectrometry. The factors affecting the separation and preconcentration of Ag(I) were optimized. Under the optimized conditions, the method exhibited a linear dynamic range of 0.5-50 μg L-1 with a detection limit of 0.04 μg L-1 and an enhancement factor of 196. A relative standard deviation of 3.2 % (n = 6) was obtained at the level of 20A μg L-1. The proposed method was successfully applied to the determination of silver in hair, nail and different water samples. The accuracy of the proposed procedure was verified by recovery experiments, independent analysis by electrothermal atomic absorption spectrometry (ET-AAS) and application of the method to the determination of silver in a certified reference material.
Bibliographic Details
http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=84928552670&origin=inward; http://dx.doi.org/10.1007/s13738-015-0618-8; http://link.springer.com/10.1007/s13738-015-0618-8; http://link.springer.com/content/pdf/10.1007/s13738-015-0618-8; http://link.springer.com/content/pdf/10.1007/s13738-015-0618-8.pdf; http://link.springer.com/article/10.1007/s13738-015-0618-8/fulltext.html; https://dx.doi.org/10.1007/s13738-015-0618-8; https://link.springer.com/article/10.1007/s13738-015-0618-8
Springer Science and Business Media LLC
Provide Feedback
Have ideas for a new metric? Would you like to see something else here?Let us know