Investigations for Analogizing PVDF and Graphene to Fabricate ECG Sensor as Wearable Device
National Academy Science Letters, ISSN: 2250-1754, Vol: 47, Issue: 5, Page: 547-549
2024
- 1Citations
- 1Captures
- 1Mentions
Metric Options: Counts1 Year3 YearSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Most Recent News
Researchers' Work from Department of Electrical and Communication Engineering Focuses on Technology (Investigations for Analogizing Pvdf and Graphene To Fabricate Ecg Sensor As Wearable Device)
2024 APR 16 (NewsRx) -- By a News Reporter-Staff News Editor at Tech Daily News -- Investigators publish new report on Technology. According to news
Article Description
In this study, the optimization of piezoelectric materials for good conductivity to measure medical recordings was investigated. For comparison, piezoelectric materials were employed. The analysis is done based on the piezoelectric materials such as lead zirconate titanate, polyvinylidene fluoride, graphene, barium titanate, combination of lead zirconate titanate with barium titanate and graphene, and combination of polyvinylidene fluoride with barium titanate and graphene. COMSOL Multiphysics 5.6 is used to carry out the simulations using different combinations of piezoelectric materials. The stress factor with displacement, electric potential, Young’s modulus owing to different loads were evaluated for different piezoelectric materials. Load variations were performed from 1 to 3 N to plot the interpolated graph. For various loadings, the output revealed good sensitivity for graphene and polyvinylidene fluoride with graphene. The dynamic area in this paper was carried out based on graphene piezoelectric material. With the applied pressure in the range 1–3 N, the final values were obtained from simulation results for PVDF with graphene material with stress factor of 4.52 MPa, the Young’s modulus value as 4.4 MPa, the electric potential obtained in the range of 3–5 µV when compared to other piezoelectric materials involved under study.
Bibliographic Details
Springer Science and Business Media LLC
Provide Feedback
Have ideas for a new metric? Would you like to see something else here?Let us know