Calibration of isothermal heat conduction calorimeters: case of flow calorimeters
Measurement, ISSN: 0263-2241, Vol: 33, Issue: 3, Page: 241-250
2003
- 20Citations
- 11Captures
Metric Options: Counts1 Year3 YearSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Article Description
In this article, the calibration of an isothermal heat conduction calorimeter used to measure the energy produced when mixing two liquids is carried out. A small amount of parameters that represents adequately the performance of the instrument has been obtained. In this sense, it has been proposed a simple model that offers a Transfer Function with two poles. The heat capacity of the injected liquids per time unit will be used as a parameter defining the validity limits of the calibration. It is shown a procedure for calibrating which consists in realizing some electrical and chemical calibrations with different pure liquids, different injection flows and mixtures with different behaviours, in order to determine the parameters of the model. This calibration is valid for the studied instrument and the used procedure is applicable to other similar thermal measuring instruments. With the calibration carried out, the studied calorimeter provides thermal measures with an uncertainty of 3%.
Bibliographic Details
http://www.sciencedirect.com/science/article/pii/S0263224102000660; http://dx.doi.org/10.1016/s0263-2241(02)00066-0; http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=0037394285&origin=inward; http://linkinghub.elsevier.com/retrieve/pii/S0263224102000660; http://api.elsevier.com/content/article/PII:S0263224102000660?httpAccept=text/xml; http://api.elsevier.com/content/article/PII:S0263224102000660?httpAccept=text/plain; https://linkinghub.elsevier.com/retrieve/pii/S0263224102000660; https://api.elsevier.com/content/article/PII:S0263224102000660?httpAccept=text/xml; https://api.elsevier.com/content/article/PII:S0263224102000660?httpAccept=text/plain; http://dx.doi.org/10.1016/s0263-2241%2802%2900066-0; https://dx.doi.org/10.1016/s0263-2241%2802%2900066-0