A fluorescent and colorimetric sensor based on ionic liquids for the on-site monitoring trace gaseous SO 2
Analytica Chimica Acta, ISSN: 0003-2670, Vol: 1232, Page: 340396
2022
- 8Citations
- 9Captures
Metric Options: Counts1 Year3 YearSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Metrics Details
- Citations8
- Citation Indexes8
- CrossRef6
- Captures9
- Readers9
Article Description
SO 2 could cause severe environmental pollution and health threat, so real-time and on-site monitoring of SO 2 has attracted considerable attention. This work proposed a novel ionic liquid-based sensor, called trihexyl (tetradecyl) phosphonium fluorescein ionic liquid, which can accurately detect SO 2 with its fluorescent and colorimetric dual-readout assay without seventeen gases interference (eg: NO, N 2, CO 2, O 2, COS, HCl, CHCl 3 ). GC-MS was also used to verify the validation of the detection method. First, this fluorescein-based IL sensor exhibited fluorescence green and colorimetric yellow signals. When the sensor was exposed to gaseous SO 2, the green fluorescence quenched, and the colorimetric yellow color faded due to chemical bond interaction. Also, the proposed IL sensor exhibited good linearity in the SO 2 concentration range of 5.0–95.0 ppm with a detection limit of 0.9 ppm (fluorescence) and 1.9 ppm (colorimetry), and recoveries of 97%∼103% with RSD less than 1.21%. Besides, the IL sensor could be easily assembled into a paper device by simple immersion, and the paper strip was exploited to realize a semiquantitative visual detection of SO 2. These results indicated that the proposed fluorescence-colorimetric dual-signal chemosensor could be used as intelligent paper labels for real-time and on-site monitoring of SO 2 in ambient air.
Bibliographic Details
http://www.sciencedirect.com/science/article/pii/S0003267022009679; http://dx.doi.org/10.1016/j.aca.2022.340396; http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=85139014209&origin=inward; http://www.ncbi.nlm.nih.gov/pubmed/36257727; https://linkinghub.elsevier.com/retrieve/pii/S0003267022009679; https://dx.doi.org/10.1016/j.aca.2022.340396
Elsevier BV
Provide Feedback
Have ideas for a new metric? Would you like to see something else here?Let us know