Experimental study and simulation analysis of heat and deformation in the water walls of an opposed firing boiler under flexible operating conditions
Applied Thermal Engineering, ISSN: 1359-4311, Vol: 213, Page: 118726
2022
- 8Citations
- 9Captures
Metric Options: Counts1 Year3 YearSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Article Description
With the extensive use of renewable energy, a large number of existing boilers will work under flexible operating conditions with low and medium loads. To study water walls safety in an opposed firing boiler under flexible load conditions, we conducted experimental research and numerical simulation for three typical flexible conditions. The results showed that compared with the single-side arrangement of burners, the opposing arrangement was beneficial for the uniform distribution of temperature and reduction of the overall thermal stress of water walls (the average stress decreased 17.9% in the opposing arrangement). In addition, a numerical simulation for calculating the distribution of the thermal stress was provided by referring to the cooling water temperature during the experimental process. Finally, an arc-shaped structure was proposed to reduce the stress of the flat plate between arc plates (the average stress reduction rate was from 7.82% to 31.99%) but induce new high stress areas. The modified structure weakened the reduction effect (the maximum thermal stress reduction rate was from 1.00% to 11.46%) but prevented high stress from water walls. The results highlight that the opposing arrangement and the modified arc-shaped structure are effective for reducing the operation risks.
Bibliographic Details
http://www.sciencedirect.com/science/article/pii/S1359431122006706; http://dx.doi.org/10.1016/j.applthermaleng.2022.118726; http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=85131436236&origin=inward; https://linkinghub.elsevier.com/retrieve/pii/S1359431122006706; https://dx.doi.org/10.1016/j.applthermaleng.2022.118726
Elsevier BV
Provide Feedback
Have ideas for a new metric? Would you like to see something else here?Let us know